Every refrigerated truck and reefer container is a box that heat constantly tries to enter. The refrigeration unit’s job is to pump that heat back out, and every watt that leaks through the walls is a watt the compressor must remove, burning diesel or drawing power the whole time.
Body builders and fleet operators have mostly focused on the refrigeration unit: more efficient compressors, better controls, electric standby. The insulated body gets less attention, even though it sets the baseline heat load the unit works against for its entire life, and that baseline gets worse as the body ages.
This article explains how wall insulation drives compressor load, why that load increases as bodies age, where low-conductivity aerogel can help, and the regulatory and practical limits that determine where it makes sense.
Where the Compressor’s Work Goes
A refrigeration unit on a truck or container deals with several heat loads at once:
- Heat transmission through the walls, roof, floor, and doors.
- Warm air infiltration every time the doors open, plus leakage through worn seals.
- Product load, including pulling down warm cargo and respiration heat from fresh produce.
- Solar gain on the roof and sides.
Insulation affects only the first, but that load never stops. It runs whether the doors are shut on a long-haul route or the truck is parked in summer sun.
The international ATP Agreement, which covers the carriage of perishable foodstuffs, measures this load directly. It classifies insulated bodies by their overall heat transfer coefficient (the K coefficient) in W/m² ·K. Normally insulated equipment (IN) must achieve K ≤ 0.70 W/m²·K, and heavily insulated equipment (IR) K ≤ 0.40 W/m²·K. ATP requires the heavily insulated class for transporting frozen food.
Transmission load follows directly from K:
Q_{transmission} \approx K \times A_{mean} \times (T_{outside} – T_{inside})
Lower K, smaller body, or smaller temperature difference all mean less work for the compressor.
Why the Load Grows as the Body Ages
Most refrigerated bodies and reefer containers are insulated with rigid polyurethane foam. It’s an excellent insulator when new, but its performance depends on the gas trapped in its closed cells. Research from the International Institute of Refrigeration shows that cyclopentane, the most commonly used blowing agent today, gradually diffuses out of the foam, raising its thermal conductivity in a process called aging. ISO 1496-2, the reefer container standard, includes these findings in an informative annex.
The effect is measurable. One review of refrigerator insulation reported polyurethane foam conductivity rising from about 0.0215 W/m·K when new to about 0.027 W/m·K in the first year, and continuing to rise gradually after that. For road vehicles, a study of refrigerated vehicle walls noted that, given the widespread availability of data, a typical loss of about 5% of insulation value per year is commonly assumed. That corresponds to about a 55% increase in energy consumption and CO₂ emissions after nine years, against a typical road vehicle service life of 10 to 15 years.
Moisture makes things worse. In reefer containers, water can enter between the wall skins and degrade the insulation, and the damage is hard to see from outside. Build quality matters as well: the same study found K values ranging from 0.82 to 1.24 W/m²·K across similar refrigerated vans, depending partly on the manufacturing process.
So the compressor load an operator sees in year eight is not the load the body was certified for in year one. The refrigeration unit runs longer, cycles more, and works harder on the hottest days, which is also when cargo is most at risk.
A Worked Example
The following is an illustrative calculation, not a measurement of any specific vehicle. Consider a medium rigid truck body with a mean surface area of about 70 m², carrying frozen goods at –20 °C on an Indian summer day at +40 °C (a temperature difference of 60 K).
| Scenario | K (W/m²·K) | Transmission load (W) |
| New body at the IR limit | 0.40 | ~1,680 |
| Same body after insulation degrades 30% | 0.52 | ~2,180 |
| Same wall thickness with an aerogel core (λ 0.016 vs 0.022 W/m·K) | ~0.29* | ~1,220 |
*Upper-bound estimate that scales K with core conductivity alone. Real bodies have thermal bridges at frames, corners, and seals that a better core doesn’t fix so the gains would be smaller. The 0.016 W/m·K figure is DashamLabs’ room-temperature value; use the manufacturer’s data at your operating temperature in real calculations.
The example shows two levers. Starting with a lower-conductivity core cuts the baseline load. Resisting the aging pushes the body from row one to row two, protecting that baseline over the vehicle’s life.
The second lever is aerogel’s material properties: unlike blowing-agent foam, aerogel doesn’t rely on a blowing agent that diffuses out over time. Independent accelerated-aging tests have found little change in aerogel thermal conductivity over simulated decades of service, as covered in our article on aerogel lifespan and aging. Aging-focused transport testing specialists have also noted aerogel’s better insulating performance than PU foam and the possibility that it avoids the aging typical of conventional materials. That was a laboratory comparison, not long-term fleet data, but it points in an encouraging direction.
Where Aerogel Fits in Practice
It would be misleading to suggest replacing all the foam in a truck body with aerogel. Polyurethane foam in a sandwich panel isn’t just insulation. It bonds to the skins, adds stiffness, and insulates. Aerogel blanket isn’t a structural core. Its value in refrigerated transport lies in targeted applications where a thin, flexible, low-conductivity layer solves a specific problem.
Thermal bridges. Door heat bypasses the main foam panels at door and corner joints, rear portal frames, wheel-arch intrusions, and the opening where the refrigeration unit mounts, which are often too tight for more foam. Thin, flexible aerogel can be fitted around them to reduce heat leaks better than panel core alone.
Address vans and conversions. In light commercial vehicles converted for refrigerated delivery, every millimeter reduces cargo space. DashamLabs lists small refrigerated vehicle and van panels as a target application. Here, aerogel’s thickness advantage lets converters reach a target K with less loss of internal width and height. DashamLabs rates its sheet at 70% lower thickness than traditional insulation. The exact saving against high-performance foam is smaller and should be calculated case by case.
Hybrid panels and upgrades. A thin aerogel layer combined with conventional foam can lower a panel’s K without much increase in thickness. This can help a body design meet the IR class more comfortably or offset some of the aging designers normally build in. See our article on hybrid insulation systems for more.
Refurbishment. When you open an aging bodypair, adding aerogel at bridges and damaged sections can restore performance without a full rebuild.
Temperature range. DashamLabs rates its sheet for continuous operation from –50 °C to 650 °C, which comfortably covers chilled and frozen transport. Its hydrophobic nature also helps, as moisture ingress is a known cause of insulation deterioration. A sound vapor barrier on the warm side remains essential.

Constraints to Respect
Several practical and regulatory limits shape where aerogel makes sense.
ATP wall thickness rules. For heavily insulated equipment, the ATP text sets a minimum sidewall thickness requirement alongside the K ≤ 0.40 limit. On equipment covered by that rule, aerogel can’t be used to make sidewalls thinner than the minimum. Its benefit there is a lower K at the required thickness. Check the current ATP text and your national authority’s interpretation before designing.
Recertification. Any change to an insulated body’s construction affects its classification. In the ATP system, an authorized ATP test station can measure K; suspected insulation deterioration also requires a K retest. Plan for testing whenever aerogel is added to a certified design.
Structure and attachment. Floors carry forklift and pallet loads, and walls carry fittings and load restraints. Aerogel: The aerogel blanket must fit within a load-carrying structure. It doesn’t replace structural panels or flooring.
Mass and payload. Insulation changes affect vehicle mass, and road vehicles work within payload limits. Evaluate panel mass alongside thermal performance for any design change.
Infiltration. If the main source of heat load on a multi-drop route is door opening, better walls alone won’t fix it. The solution needs strip curtains, faster door cycles, and good seal maintenance.
How to Evaluate Aerogel for Your Fleet or Body Design
The most reliable approach is to measure before and after.
- Establish the baseline. Find out the current K value of your bodies, ideally from a recent ATP test, or estimate it from refrigeration unit run-time data.
- Find the heat leaks. Thermal imaging of a chilled body in warm ambient conditions quickly shows where heat is getting in: frames, corners, doors, and unit mounts.
- Model the options. Calculate the effect of aerogel at the bridges, as a hybrid layer, or as full wall insulation in a van conversion, using conductivity data at your operating temperatures.
- Build and test a prototype. Measure K at an authorized test station and compare unit run time on the same route.
- Factor in aging. Compare the cost over the vehicle’s life, not just in year one, since foam degradation affects the long-term case for any insulation change.
DashamLabs supplies sample sheets in 3, 5, and 10 mm thicknesses for prototyping and pilot projects. You can request a sample or review the full technical specifications.
The Bottom Line
In refrigerated transport, the insulated body sets the heat load the compressor works against every hour of its working life. That load rises as polyurethane foam ages and moisture enters the walls, so a body’s energy cost increases steadily over its service life. Aerogel isn’t a drop-in replacement for structural foam panels, but a flexible, non-aging layer that can address thermal bridges, recover cargo space in vans, lower K in hybrid designs, and help bodies maintain performance longer. Combined with ATP-compliant design and recertification testing, that means less compressor work and lower running costs.