Aerogel Insulation FAQs: 25 Questions Engineers Ask Before Buying

Oct 29, 2026 | Blogs

When aerogel comes up on a project, engineers and buyers often ask the same questions about thermal performance, temperature limits, moisture, fire, installation, standards, and cost. This FAQ answers 25 of them directly, with references to the standards and research behind each answer. Where the honest answer is “it depends” or “ask for test data,” we say so.

The Basics

1. What is silica aerogel insulation?

Silica aerogel is a solid made mostly of air, held within a nanoscale silica network. On its own, it’s fragile, so industrial insulation products combine it with a fibrous reinforcement to make flexible blankets or sheets. DashamLabs produces aerogel blanket insulation this way, combining silica aerogel with flexible reinforcement layers to make durable, easy-to-install blankets.

2. Why is its thermal conductivity so low?

Most heat in porous insulation travels through the gas trapped in the pores. In aerogel, the pores are so small that air molecules collide with the pore walls more often than with each other, which suppresses heat transfer through the gas. The very fine, tortuous solid network also limits heat conduction through the solid. As a result, its thermal conductivity is well below that of conventional fibrous or foam insulation.

3. What thermal conductivity should I use in calculations?

DashamLabs’ flexible silica aerogel sheet has a thermal conductivity of about 0.016 W/m·K at room temperature, with a published range of 0.016–0.030 W/m·K. As with all insulation, conductivity rises with temperature, so use the value at your insulation’s mean operating temperature, not the room-temperature headline figure. For background, see our guide to lambda, R-value and U-value.

4. How much thinner is aerogel than conventional insulation?

DashamLabs rates its sheet as 70% thinner than traditional insulation. The savings on a specific project depend on what you’re replacing and the operating temperatures of both materials. In a worked steam-line example using illustrative conductivity values, aerogel matched the heat loss of a conventional material at roughly 60% less thickness. The best approach is to calculate the thickness each material needs to meet the same heat-loss or surface-temperature target.

5. In what formats is it supplied?

DashamLabs supplies aerogel blanket insulation in several thicknesses, including 10 mm, and makes blanket solutions tailored for piping, vessels,s and industrial equipment. Samples for testing and pilot projects are available as 1 m² sheets in 3, 5 and 10 mm thicknesses.

Temperature and Environment

6. What temperature range does it cover?

DashamLabs rates its sheet for continuous operation from –50 °C to 650 °C. For context, ASTM C1728, the product specification for flexible aerogel insulation, covers continuous operating temperatures from –196 °C to 649 °C across the product types it defines. Always check the rated range of the specific product you’re buying.

7. Can it be used for cryogenic service such as LNG?

Aerogel is used in cryogenic service, but DashamLabs’ stated minimum is –50 °C. Applications colder than that, including LNG and liquid nitrogen, fall outside its stated range and would need product-specific qualification. For cold service within the range, a vapor retarder is essential (see question 9).

8. Does thermal conductivity change with temperature?

Yes. Thermal conductivity rises with temperature for aerogel and every other common insulation material. That’s why datasheets that give only a room-temperature value aren’t enough for hot or cold service. Ask for conductivity data across your operating range.

9. Is aerogel waterproof?

Hydrophobic aerogel strongly repels liquid water, which is a real advantage over fibrous materials that wick and hold water. But repelling liquid water isn’t the same as being unaffected by humid air. Studies of aerogel-based products have found that humidity affects thermal conductivity much more than temperature does; one study found conductivity doubled at 95% relative humidity. For below-ambient service, ASTM C1728 requires properly installed vapor retarders because, without them, the insulation system may fail to perform.

10. Does aerogel lose its hydrophobicity at high temperatures?

It can, at the hot face. The water repellency of most silica aerogels comes from methyl groups on the silica surface, which are thermally sensitive. In one study, hydrophobic silica aerogel changed little below 350 °C, but its water contact angle dropped from 139° to 44° between 350 °C and 400 °C. The silica structure itself remains. Because temperature falls through the insulation thickness, the outer layers usually stay cooler and keep their water repellency. For hot service, ask the manufacturer for hydrophobicity retention data at your operating temperature and discuss the temperature profile across the layers.

11. Can aerogel prevent corrosion under insulation (CUI)?

Aerogel helps, because a hydrophobic insulation that doesn’t hold water removes one of the main conditions for CUI. DashamLabs describes its aerogel as fully hydrophobic and designed to prevent corrosion under insulation. CUI prevention is still a system issue: cladding, sealing, coatings, and leak repair all matter. The DOE advises repairing or replacing damaged or wet insulation immediately and fixing the source of moisture first. See our article on CUI and asset life for more.

12. Is it safe to install on stainless steel?

Insulation in contact with austenitic stainless steel can contribute to stress corrosion cracking if it contains leachable chlorides. ASTM C795 sets the requirements for insulation used in contact with austenitic stainless steel, including the C692 stress corrosion test and C871 chemical analysis for leachable chloride, fluoride, silicate, and sodium. If your lines are stainless, ask any supplier, DashamLabs included, for C795 test results before approval.

Fire and Safety

13. Is aerogel insulation combustible?

Silica itself doesn’t burn, but most hydrophobic aerogels contain organic surface groups that do, and research identifies these groups as the main source of fire risk in hydrophobic silica aerogel. That’s why the product’s fire classification matters more than the material class. Ask for test reports for the classification your project needs, such as ASTM E84 or E136 in the US system, or EN 13501-1 in Europe, where Class A1 requires both the EN ISO 1182 non-combustibility test and the EN ISO 1716 heat of combustion test. Make sure the report covers the same thickness and configuration you’ll install.

14. Is aerogel dust hazardous?

Silica aerogel is amorphous silica, not crystalline silica, which is the form associated with silicosis. Manufacturers’ safety data sheets describe aerogel dust mainly as a physical irritant that can cause temporary irritation of the eyes, skin, and throat, and note that studies on amorphous silica show low potential for adverse health effects. Because the material is hydrophobic, it can also dry the skin. Installers should follow the product’s safety data sheet: wear gloves and eye protection, and use dust control or respiratory protection when cutting.

15. What surface temperature should insulation achieve for personnel protection?

ASTM C1055 sets 5 seconds as the probable contact time for industrial situations and recommends limiting injury to a first-degree burn. In practice, many plants design for an outer surface temperature of about 60 °C or below on touchable surfaces. Include this check when sizing insulation, especially on small or very hot lines and with metal cladding.

Design

16. How do I calculate the thickness I need?

For flat surfaces, thermal resistance is thickness divided by conductivity. For pipes, use the logarithmic formula for cylindrical insulation, because each extra millimeter adds less resistance than the one before. Use conductivity at the mean operating temperature, and calculate heat loss and surface temperature together. The DOE recommends 3E Plus, free software that calculates optimum thickness for many insulation materials and reports payback, heat loss, and surface temperature.

17. How do I find the most cost-effective thickness?

Use economic thickness of insulation: the thickness at which installed insulation cost plus the cost of remaining heat loss is lowest over the evaluation period. India’s Bureau of Energy Efficiency lists the inputs: fuel cost, operating hours, fuel heat content, boiler efficiency, surface temperature, pipe diameter, insulation cost, and ambient temperature. Run the analysis for each candidate material and compare their minimum total costs. See our article on economic thickness of insulation for a worked example.

18. Can aerogel insulate valves, flanges and irregular fittings?

Yes, and this is one of its strongest applications. Flexible blankets conform to complex shapes, and the thin profile helps jackets close around crowded hardware. For components that need regular access, use removable, reusable jackets. The DOE describes them as having a noncombustible inner cover, an insulation core, and a tear- and abrasion-resistant outer cover, fastened with laced wire or buckled straps. ASTM C1695 sets fabrication requirements for removable blanket insulation in hot service up to 538 °C.

19. Does aerogel need cladding or jacketing?

On outdoor lines and anywhere exposed to mechanical damage, washdown,n or weather, yes. Cladding protects the insulation and keeps water out. For cold service, you also need a vapor retarder. In practice, the cladding and sealing details often decide how long an insulation system lasts.

20. Can aerogel be combined with conventional insulation?

Yes. Hybrid systems put aerogel where space is tightest, temperatures are highest, or moisture risk is greatest, and use conventional insulation elsewhere to manage cost. In hot multi-layer builds, layer order also affects how temperature is distributed through the system. See our article on hybrid insulation systems for more.

Installation

21. How is aerogel blanket cut and installed?

Flexible aerogel blankets can be cut to exact dimensions with standard cutting tools, which keeps waste low. Installation generally follows normal blanket insulation practice: wrap or layer to the design thickness, stagger joints between layers, secure with bands or wire, and finish with cladding or jacketing. The application and finishing practices in IS 14164 apply to Indian projects. Control dust when cutting and follow the safety data sheet.

22. Does compression affect performance?

Moderate compression doesn’t seriously harm aerogel blankets. In one study, after 20 compression-and-release cycles, thermal conductivity changed by 5% or less, and permanent deformation by 6% or less. Still, avoid over-tightening bands and fasteners. DashamLabs’ own installation guidance warns that over-compressing aerogel can significantly reduce its insulating performance.

Standards, Lifespan and Buying

23. Which standards apply to aerogel insulation?

The main product specification is ASTM C1728, which covers the classification and performance of flexible aerogel insulation, including thickness, density, flexibility, and Types I, II, and III. Relevant test methods include ASTM C177, C518, and C335 for thermal conductivity, ASTM C795 for stainless steel contact, and ASTM or EN methods for fire. In India, IS 14164 is the code of practice for industrial application and finishing of thermal insulation from –80 °C to 750 °C. For the full picture, see our buyer’s compliance checklist for ASTM, EN and IS standards.

24. How long does aerogel insulation last?

There’s no fixed expiry date. Insulation’s life ends when its performance falls outside acceptable limits. Accelerated-aging studies are encouraging. One study simulating 20 years of outdoor heat, humidit,y and sunlight found no change in the thermal conductivity of aerogel mats. Another found typically less than a 10% increase for aging equivalent to 20 years under typical conditions. In practice, moisture ingress through failed cladding or vapor barriers, mechanical damage, and very high temperatures at the hot face limit service life. See our article on aerogel lifespan, aging and warranty for more.

25. Is aerogel worth the higher price, and how do I evaluate it?

Aerogel costs more per square millimeter than conventional insulation, so judge it on total cost of ownership, not material price. It tends to pay off where space is limited, where fittings and complex shapes need conformable insulation, where moisture and CUI are known problems, or where thinner insulation reduces cladding, support, or layout costs. It’s often not the cheapest option on long, open runs with plenty of space. The most reliable way to decide is to run economic thickness calculations for each candidate material, then test a sample in your own application. Customers can buy aerogel insulation directly from DashamLabs. To start, review the technical specifications or request a sample.